Engineering Dossier · EN 14351-1 Standard

CE Certified Aluminium Flush Casement Windows Manufacturer & Factories

Architectural flush-fitting fenestration systems engineered with thermal barrier technology, weather tightness Class 9A, and structural precision for high-performance residential and commercial developments.

180,000
Square Meters Facility
25+
Years Engineering Heritage
100+
Patents & Global Certs
0.85
W/m²K Lowest Uw Value

Precision Flush Casement, Specialized Glazing & Architectural Systems

Explore our engineered fenestration units, manufactured to exacting European and North American code benchmarks with comprehensive thermal break profiles and flush-line aesthetic continuity.

Engineering Specifications for CE-Certified Flush Casement Windows

A technical evaluation framework for architects, specifiers, facade consultants, and general contractors seeking verified fenestration envelopes that satisfy European EN 14351-1 and international building standards.

Technical Executive Summary: Flush casement windows have transitioned from a niche architectural styling to a dominant facade paradigm across European, North American, and Australasian high-performance building developments. The structural hallmark of an aluminium flush casement window is its coplanar alignment, wherein the operable window sash sits entirely flush with the outer perimeter frame, delivering uninterrupted exterior plane continuity. Achieving this without compromising air permeability, thermal breaks, or structural wind load integrity requires strict precision tolerances (±0.5mm), engineered multi-chambered polyamide thermal bridges (PA66 GF25), and calibrated multi-point perimeter compression locking gear.

Coplanar Architectural Geometry

By engineering recessed hinge systems and coplanar profile rebates, our flush casement assemblies eliminate exterior sash overhangs. The clean perimeter shadow gap delivers minimalist sightlines sought after in contemporary residential architecture and heritage restoration projects requiring modern envelope performance.

Thermal Barrier Architecture (PA66 GF25)

We incorporate structural 24mm to 34mm polyamides reinforced with 25% glass fiber. These multi-cavity thermal isolators mechanically decouple external temperature spikes, neutralizing thermal conductance and yielding whole-window U-values down to 0.85 W/m²K when combined with warm-edge triple argon IGU packages.

Dual & Triple EPDM Gasket Envelopes

Perimeter airtightness in coplanar assemblies relies on continuous vulcanized EPDM center and acoustic rebates. Our co-extruded gaskets maintain elastic memory across extreme freeze-thaw cycles (-40°C to +80°C), preventing condensation pooling and preventing air leakage under elevated differential pressure.

Comparative Performance Analysis: Flush Casement vs. Traditional Windows

Quantitative verification standards based on EN 14351-1 testing protocols across structural, thermal, and barrier metrics.

Performance Characteristic Test Standard Generic Non-Thermal Window Standard European Casement DERCHI CE Flush Casement
Air Permeability EN 12207 Class 2 (300 Pa) Class 3 (600 Pa) Class 4 (600 Pa Max Pressure)
Water Tightness EN 12208 Class 4A (150 Pa) Class 7A (300 Pa) Class 9A / E1050 (1050 Pa)
Wind Load Resistance EN 12210 Class B2 (800 Pa) Class C3 (1200 Pa) Class C5 / B5 (2000+ Pa)
Thermal Transmittance (Uw) EN ISO 10077-2 > 3.2 W/m²K 1.6 – 2.0 W/m²K 0.85 – 1.30 W/m²K
Acoustic Attenuation (Rw) EN ISO 717-1 26 dB (Single Glaze) 32 dB (Std Double) Up to 44 dB (Laminated IGU)
Structural Alloy Spec EN 573-3 / ASTM B221 Recycled Mixed Scrap 6063-T5 Standard Primary Virgin 6063-T6 / 6060
Sash Alignment Plane Visual / Dimensional Projecting / Stepped Rebate Overlapping Lip (8-12mm offset) 100% Seamless Coplanar Flush

Emerging Procurement Trends in Architectural Aluminium Fenestration

Strategic purchasing considerations shaping the decisions of commercial builders, property developers, and overseas distribution partners through 2030.

Why Tier-1 Contractors Partner with Guangdong Dejiyoupin (DERCHI)

Operating from our modern industrial headquarters in Shishan Town, Nanhai District, Foshan, we provide high-capacity volume fenestration engineering backed by over two decades of international export excellence.

180,000 m² Facility

One of China's largest intelligent door and window industrial parks, featuring precision German Elumatec CNC profile processing centers.

600+ Skilled Specialists

Dedicated fabrication artisans, structural envelope engineers, and quality assurance inspectors overseeing every assembly stage.

100+ Patents & Certs

Comprehensive international compliance including European CE (EN 14351-1), Australian AS 2047, North American NFRC, ISO 9001, and UL fire safety.

Direct Global Export

Heavy-duty reinforced plywood crating, humidity-sealed container packing, and full customs coordination for port deliveries worldwide.

Frequently Asked Questions on CE Flush Casement Windows

Direct technical answers addressing engineering verification, testing standards, containerized logistics, and custom specification parameters.

What specific testing criteria must an aluminium flush casement window satisfy for valid CE marking?
Under the mandatory European harmonized standard EN 14351-1 (Windows and Doors - Product standard, performance characteristics), aluminium flush casement windows must undergo official Type Testing (ITT) by an accredited notified laboratory. The required performance evaluations include:
  • Air Permeability (EN 12207): Must attain Class 3 or Class 4 (maximum airtightness at 600 Pa test pressure).
  • Water Tightness Under Static Pressure (EN 12208): Validated up to Class 9A or higher (resisting water penetration up to 600 Pa, with custom DERCHI systems achieving Class E1050 / 1050 Pa).
  • Resistance to Wind Load (EN 12210): Tested for structural frame deflection under positive and negative pressures (typically Class C3 up to Class C5 for high-rise or exposed envelopes).
  • Thermal Transmittance (EN ISO 10077-1 & EN ISO 10077-2): Calculation and hot-box verification of overall Uw values, factoring profile frame Uf and glass Ug metrics.
  • Load-Bearing Capacity of Safety Devices: Verification that hinge limiters and friction stays withstand a minimum sustained load of 350 N without failure.
Every export consignment from our Foshan facility is accompanied by formal Declaration of Performance (DoP) certificates and compliant CE marking tags.
How do aluminium flush casement windows prevent water leakage given their flush exterior profile?
Unlike traditional projecting sashes where an overlapping exterior lip acts as a basic drip ledge, a true flush system sits co-planar with the frame. Preventing water infiltration under wind-driven storm conditions requires advanced pressure-equalization engineering:

1. Pressure-Equalized Decompression Chamber: The rebate area between sash and frame is engineered so internal cavity pressure instantly balances with external atmospheric wind pressure, removing the pressure differential that pulls rainwater inwards.
2. Continuous EPDM Vulcanized Gaskets: Dual or triple co-extruded synthetic rubber gaskets create impenetrable barriers. The primary center gasket isolates the wet exterior drainage zone from the dry interior thermal zone.
3. Concealed Cascade Sub-Sill Drainage: Precision CNC-milled drainage slots with anti-backdraft one-way flap valves allow any moisture entering the outer channel to escape downward via gravity, preventing pooling even during 100+ km/h squalls.
What alloy compositions and thermal break materials are specified for heavy commercial use?
We construct all load-bearing profiles using virgin architectural primary billet 6063-T6 or 6060-T6 aluminium alloy complying with EN 573-3 and EN 755 tolerances. We maintain wall thicknesses between 1.6mm and 2.2mm depending on structural mullion calculations.

For thermal isolation, we use genuine polyamide PA66 reinforced with 25% chopped glass fiber (PA66 GF25) strips inserted via knurled extrusion channels and mechanically crimped on automated German rolling lines. This composite matches the thermal expansion coefficient of aluminium (2.3 × 10⁻⁵ K⁻¹), preventing shear stress delamination or structural deformation during extreme diurnal temperature swings.
Can you manufacture flush casement windows according to imperial architectural schedules and custom finishes?
Yes. As an OEM/ODM manufacturing partner for general contractors, facade consultants, and builders across North America, the UK, and Australia, we fabricate 100% bespoke window schedules. You can provide dimensions in millimeters or imperial fractions of an inch.

Our automated architectural finishing operations support:
  • Qualicoat Class 1 & Class 2 Architectural Powder Coating: In standard RAL palettes, textured architectural architectural finishes, and ultra-durable fluoropolymer coatings designed for high-UV exposure.
  • Qualanod Certified Anodizing: From natural silver and champagne to dark bronze and deep black (15 to 25 microns film thickness) engineered to resist marine salt-fog corrosion.
  • PVDF Coatings (AAMA 2605 compliant): Utilizing 70% Kynar 500 resin for 20+ year color retention on luxury commercial facades.
What is your production lead time, export packaging, and container consolidation process?
Our standard manufacturing timeline runs 25 to 35 calendar days following final sign-off on detailed CAD shop drawings and hardware finishes.

For overseas ocean freight transit, each window unit undergoes a four-tier packaging protocol: 1. Protective static surface film applied to all exposed aluminium profiles. 2. High-density shock-absorbing EPS foam corner caps. 3. Moisture-sealed thick polyethylene thermal shrink-wrap. 4. Custom ISPM-15 compliant fumigation-free solid multi-layer plywood crates with integrated lifting skids.

We routinely load 20GP, 40GP, and 40HQ high-cube shipping containers directly on our factory docks, optimizing container space and securing crates with heavy-duty polyester strapping and structural dunnage airbags to prevent cargo shifting during transoceanic transit.
How does DERCHI support architects and specifiers before production begins?
We provide end-to-end technical pre-construction services. When you submit your architectural elevations and window schedules, our in-house engineering team provides:
  • Comprehensive 2D DWG/DXF and 3D BIM/Revit shop drawings illustrating rough opening clearances, structural fixing brackets, sub-sill flashing integration, and perimeter vapor seal interfaces.
  • Finite element thermal simulations (ISO 10077-2 calculations) showing project-specific isotherm charts and calculated Uw values.
  • Structural wind load calculations (taking into account building height, exposure category, and local wind speed factors) to confirm mullion moment of inertia (Ix) adequacy.

Request Engineered Shop Drawings & Factory B2B Quotations

Submit your architectural drawings, tender schedules, or rough opening dimensions. Our experienced bilingual fenestration engineers will provide custom CAD shop drawings, glass optimization reports, and direct-factory pricing within 24 business hours.

Inquire Now