Manufactured under strict ISO 9001 and CE execution classes. Explore our synchronized production lines covering heavy-duty double swings, thermal pivot apertures, panoramic bifold configurations, and high-performance commercial enclosures.
In high-traffic commercial environments, multi-family developments, and luxury exterior architectural designs, aluminum double swing doors represent both a primary aesthetic statement and a critical envelope barrier. Achieving genuine CE marking under the European Union Construction Products Regulation (CPR 305/2011) and harmonized norm EN 14351-1 requires far more than basic visual assembly. It demands verified Factory Production Control (FPC), rigorous third-party Type Testing (ITT), and quantifiable performance declarations regarding air permeability, watertightness, wind resistance, and thermal transmittance (U-value).
Guangdong Dejiyoupin Doors and Windows Co., Ltd. (DERCHI) leverages 25+ years of precision manufacturing to engineer architectural aluminum double swing doors that systematically outperform standard fenestration benchmarks. Utilizing primary billet 6063-T6 and 6061-T6 architectural aluminum alloys with wall thicknesses reaching 2.0mm to 3.0mm, our double swing assemblies withstand extreme dynamic cyclic loads while preserving dimensional stability across thermal fluctuations from -40°C to +80°C.
Core Technical Directive: True CE conformity for double swing doors mandates dual-leaf synchronization testing, drop-seal pressure mitigation, and multi-point perimeter compression locking to eliminate center-meeting stile air infiltration under positive and negative gale pressures.
By pairing structural thermal barrier strips—composed of 25% glass-fiber reinforced polyamide 6.6 (PA66 GF25)—with multi-cavity isobaric chamber architecture, DERCHI double swing doors disrupt continuous thermal bridges. This structural strategy controls interior condensation risk while driving overall fenestration U-values down to compliant passive building levels (Ud ≤ 1.1 W/m²·K when configured with argon-filled triple insulating glass units).
From metallurgical casting inspection to CNC 5-axis profile machining, DERCHI consolidates architectural door manufacturing under one 180,000 square meter roof.
Our production protocols conform comprehensively to CE (EN 14351-1), Australian AS 2047 cyclic testing up to Serviceability Limit State (SLS) N6 rating, and American UL fire endurance guidelines. Importers and general contractors receive fully traceable Mill Test Certificates (MTC) and Declaration of Performance (DoP) dossiers with each shipment batch.
Equipped with computerized multi-axis Italian machining centers, our automated lines mill, drill, and tap hardware preps with sub-millimeter tolerances (±0.2mm). Every concealed hinge socket, concealed overhead transom closer, flush drop-down threshold seal, and shoot-bolt channel is machined prior to surface finishing to protect aluminum from corrosion initiation.
North American and European developers benefit from our specialized design office. Our engineers translate rough openings and architectural door schedules into complete parametric CAD submittals, anchorage calculation reports, and IFC/Revit BIM models within 48 hours, eliminating jobsite discrepancies before extrusion cutting begins.
Comparative performance analysis established according to EN and ISO normative test procedures for commercial aluminum double swing assemblies.
| Performance Parameter | Test Standard (EN / ISO) | Commercial Grade Baseline | DERCHI Heavy-Duty Double Swing | Regulatory Status |
|---|---|---|---|---|
| Air Permeability | EN 1026 / EN 12207 | Class 2 (300 Pa) | Class 4 (600 Pa max pressure) | CE Compliant |
| Watertightness | EN 1027 / EN 12208 | Class 4A (150 Pa) | Class 9A / E900 (900 Pa static head) | Exceeds Norm |
| Resistance to Wind Load | EN 12211 / EN 12210 | Class B2 (800 Pa) | Class C5 (±2000 Pa test, ±3000 Pa safety) | Hurricane Rated |
| Thermal Transmittance (Ud) | EN ISO 10077-1/-2 | 2.2 – 2.6 W/(m²·K) | 0.98 – 1.35 W/(m²·K) (Triple/Low-E) | Passive House Fit |
| Acoustic Attenuation (Rw) | EN ISO 10140-2 | 28 – 32 dB | 38 – 44 dB (Acoustic PVB Lamination) | Acoustic Shield |
| Mechanical Durability | EN 1191 / EN 12400 | 100,000 cycles (Class 5) | 1,000,000 cycles (Class 8 High Frequency) | Severe Duty |
How shifting sustainability policies, smart building management, and automated access technologies are redefining commercial door supply chains globally.
Stringent EU CBAM (Carbon Border Adjustment Mechanism) mandates are driving global buyers toward aluminum extruded with post-consumer recycled scrap and renewable hydro-powered smelting. DERCHI proactively supplies verifiable EPD (Environmental Product Declaration) dossiers validating embodied carbon under 4.0 kg CO2e/kg Al.
Traceability through QR-linked RFID tags embedded in profile channels will soon be mandatory across European markets. These digital passports store thermal ratings, maintenance logs, chemical composition of coatings, and disassembly instructions for end-of-life circular metal reclamation.
Architects are eliminating surface-mounted hardware. Future double swing systems natively integrate 24V DC concealed motorized latches, electromagnetic hold-open floor springs, and micro-embedded biometric / RFID scanners linked directly to master BACnet or KNX building automation protocols.
Inclusive architectural design codes (ADA in the USA, DIN 18040 in Germany) require completely level transition thresholds (≤0mm to 2mm). Next-generation CE doors employ mechanical magnetic twin-gasket drop seals that only deploy downward upon the final swing closure cycle.
The historical engineering challenge of any double swing door—frequently termed double casement or French doors—lies in the junction of the primary (active) and secondary (passive) leaf. Without a fixed vertical mullion, the meeting stile must resist severe differential thermal bowing (the "bimetallic effect") when summer sun creates an 80°C exterior surface while interior air conditioning maintains 22°C.
DERCHI solves this structural issue by implementing three-point anti-distortion thermal isolation strips and interlocked dual astronomical astragals fitted with closed-cell EPDM co-extruded gaskets. Unlike standard PVC seals which degrade, harden, and shrink under UV exposure, our continuous Vulcanized EPDM weathering barriers maintain high elasticity across decades of cyclic pressure.
Kinematic Reinforcement: We incorporate 3D adjustable concealed heavy-duty 304 stainless steel pivot hinges capable of carrying up to 300kg per leaf without vertical sag or lateral displacement, ensuring lifelong fingertip operation.
Furthermore, our powder-coating plants utilize world-class thermosetting fluoropolymer (PVDF) and AkzoNobel Qualicoat Class 2 architectural powders, delivering salt spray resistance in excess of 3,000 hours under ASTM B117 standards—an imperative attribute for coastal installations throughout North America, the Caribbean, and Australasia.
Direct, technically exhaustive responses addressing structural codes, shipping consolidation, testing reports, and custom architectural door fabrication.
Genuine CE compliance requires a Declaration of Performance (DoP) issued by the manufacturer referencing harmonized standard EN 14351-1:2006+A2:2016, supported by Initial Type Test (ITT) reports from an accredited European Notified Body (Notified Testing Laboratory). The documentation must formally quantify air permeability, watertightness, dangerous substances release, load-bearing hardware capacity, and thermal transmittance (U-value). DERCHI provides full DoP documents, CE marking stickers, and laboratory test certificates for project submittals.
In double swing systems lacking a center mullion, the meeting stile is sealed through overlapping interlocking aluminum astragals equipped with dual or triple EPDM fin gaskets. DERCHI utilizes an integrated internal shoot-bolt system combined with automatic drop-down bottom acoustic/water seals and continuous corner vulcanized gaskets. When the active leaf latches against the passive leaf, multi-point compression locks draw both leaves into uniform compression against the outer frame rebated perimeter.
Yes. DERCHI operates custom manufacturing lines configured to build directly to architectural schedules in both imperial (inches/feet) and metric units. Whether your project specifies an oversized 8'0" × 10'0" grand entrance or non-standard commercial egress openings, our in-house engineering team generates detailed shop drawings, rough opening tolerances, anchoring engineering calcs, and hardware templates for sign-off prior to extrusion cutting.
All finished double swing door frames and sashes are protected with peelable protective film, bubble-wrap impact buffering, and edge corner armor. Assemblies are packed into heavy-duty fumigated wooden crates constructed with internal steel reinforcement bands and vertical desiccants to mitigate maritime condensation. For high-volume projects, we pack frames knocked-down (KD) with numbered CNC corner bracket joints or fully glazed pre-hung frames secured in custom steel transport racks.
For cold climate zones (such as Canada, the Northern US, Scandinavia, and Alpine regions), we specify multi-cavity thermally broken profiles fitted with 34mm to 44mm Technoform or equivalent PA66 GF25 polyamide insulation struts. These profiles are filled with low-density polyolefin insulation foam and glazed with triple-pane insulated glass units (argon filled, warm-edge spacers, double Low-E coatings), achieving overall system U-values as low as 0.95 W/(m²·K).
Yes. Our commercial and residential double swing series can be pre-wired and factory-prepped for electrified multi-point mortise locks, hidden concealed door loops, maglock shear pins, and panic crash exit bars conforming to EN 1125 / UL 305. The concealed wiring conduits run internally through the thermal break cavity without penetrating weather-barrier seals or compromising thermal continuity.
Collaborate directly with our Foshan manufacturing team. Submit your architectural door schedules, CAD plans, or tender specifications. Our technical engineering division will generate full CAD shop drawings, structural wind-load verifications, and competitive direct-factory quotations within 24 to 48 hours.
Send an Inquiry